Technical guide & safety

How aircon refrigerant refills actually work

Your air conditioner operates in a closed loop. Learn how proper manifold pressure testing, leak isolation, and weight-based charging restore real cooling without damaging your compressor.

The 3-stage charging protocol

Why simply adding gas without diagnosis leads to repeat failures.

01

Pressure & temperature diagnostic

120 – 140 PSI (R410A)

Technicians connect a digital manifold gauge to check low and high-side operating pressures against manufacturer specifications.

02

Electronic leak test

Zero undetected leaks

Refrigerant does not naturally run out. We inspect flare joints, evaporator coils, and service valves before adding any gas.

03

Controlled weight charge

Accurate to +/- 5g

Gas is weighed to exact factory gram specs using digital charging scales, preventing compressor overload or icing.

The closed-loop principle

Refrigerant is never consumed like petrol. If gas levels are down, there is a mechanical leak in copper piping, flare nuts, or the cooling coil. Top-ups without repair only provide temporary relief.

Singapore HDB & Condo standard
Refrigerant types compared
Different systems use distinct chemical blends and working pressures.

R32 Refrigerant

Current standard
  • Higher efficiency
  • 675 GWP (Low climate impact)
  • Best for: Modern inverter split units

R410A Refrigerant

Prevalent in older systems
  • Standard high-pressure blend
  • 2,088 GWP
  • Best for: Older residential multi-split setups
Safe operating signs after proper top-up
12°C – 16°CDischarge air temp
Even sweatingSuction pipe moisture

Unsure if you need gas?

Get an on-site pressure reading before committing.

Request an on-site pressure check

Calibrated manifold tools

Accurate pressure bars preventing overcharge stress on valves.

EPA-aligned safety

Environmentally responsible recovery and venting protocols.

Full diagnostic report

Written PSI and temperature differential recorded on invoice.

Transparent pricing

No hidden top-up fees without confirmed leak inspection.

Technical guide

How aircon refrigerant works, and when you need a top-up

Air conditioning systems operate in a completely sealed, closed loop. Refrigerant never gets used up like fuel; pressure drops only happen when there is a mechanical leak.

Thermodynamic loop

The 4-stage cooling cycle

Refrigerant continuously alternates between liquid and gas states, carrying indoor heat outdoors through phase changes.

STAGE 01
Evaporator absorbs indoor heat
Low pressure liquid to gas

Cold liquid refrigerant passes through indoor coils, drawing hot air out of your living space and turning into gas.

STAGE 02
Compressor pressurizes gas
High pressure hot vapor

The outdoor compressor pumps and squeezes the vapor, raising both its temperature and internal pressure.

STAGE 03
Condenser expels outdoor heat
High pressure gas to liquid

Outdoor fan units vent the collected heat into the outside air as refrigerant condenses back to liquid form.

STAGE 04
Expansion valve cools liquid
Low pressure cold liquid

A precision valve rapidly drops the pressure, chilling the liquid before it recirculates to the indoor unit.

Diagnosis & repair

Why does gas leak in a closed system?

Because aircon systems are pressurized closed circuits, refrigerant does not evaporate into thin air on its own. If your gas level is low, one of these three mechanical issues is the root cause.

Copper joint vibration

Years of compressor vibration can loosen flare joints and flare nuts along the copper piping network.

Typical sign:Hissing noise or oily residue around brass connections

Pinhole pipe corrosion

High humidity and formicary corrosion can create microscopic pinholes in thinner aluminum or copper fins.

Typical sign:Gradual cooling drop over several weeks or months

Faulty service valves

Rubber seals and Schrader valves on outdoor condenser units can degrade under direct tropical sun exposure.

Typical sign:Ice formation on the outdoor valve stem

Topping up without finding the leak is only a temporary fix.

EZ Aircon technicians always perform a pressure gauge test to confirm leak locations before refilling.

Check service prices
Safety standard

Correct gas matching matters

Aircon compressors and expansion valves are calibrated for specific operating pressures and lubricant oils. Mixing or using incorrect gas damages equipment and creates safety hazards.

R32Current standard
Recommended
Operating pressure:High (approx. 120-140 PSI)
Global warming potential:675 (low impact)
Flammability rating:A2L (mildly flammable)

Standard in newer inverter units. Highest energy efficiency and one-third the global warming impact of older gases.

R410APrevious generation
Legacy / Specific
Operating pressure:High (approx. 110-130 PSI)
Global warming potential:2,088 (moderate)
Flammability rating:A1 (non-flammable)

Found in units installed between 2010 and 2021. Blended refrigerant requiring exact liquid-phase charging.

R22Phased out
Legacy / Specific
Operating pressure:Low (approx. 60-70 PSI)
Global warming potential:1,810 (ozone-depleting)
Flammability rating:A1 (non-flammable)

Older non-inverter models. Production strictly restricted; system conversions or upgrades recommended.

Unsure which refrigerant your aircon model uses?

Our Singapore technicians inspect outdoor unit nameplates and conduct electronic manifold checks before any gas top-up.

Refrigerant Identification Guide

Find the right refrigerant for your aircon

Using the correct gas maintains cooling pressure, protects the compressor from breakdown, and meets Singapore NEA environmental regulations.

Phased Out in SGPre-2010 units
R22
Chlorodifluoromethane

Cooling Efficiency

Moderate (High Energy Loss)

Ozone Impact

Contains HCFCs (Damages Ozone)

Global Warming Potential

1,810 (High GWP)

Market Status

Restricted supply, higher refill cost

Technician Note: Consider retrofitting or upgrading to modern inverter systems.

Common StandardStandard in most homes
R410A
HFC Blend (R32 / R125)

Cooling Efficiency

High cooling capacity

Ozone Impact

Zero Ozone Depletion

Global Warming Potential

2,088 (Standard GWP)

Market Status

Widely available across Singapore

Technician Note: Standard choice for most non-inverter and early inverter units.

Recommended
Eco-Friendly ChoiceModern 5-tick inverters
R32
Difluoromethane

Cooling Efficiency

Highest efficiency (Uses 30% less gas)

Ozone Impact

Zero Ozone Depletion

Global Warming Potential

675 (68% Lower GWP)

Market Status

Standard for new installations

Technician Note: Recommended for modern energy savings and lower carbon footprint.

Simple Verification

How to confirm your aircon gas type

Follow these three simple steps before requesting a gas top-up service.

STEP 01

Check outdoor condenser label

Look at the silver metal rating plate on your outdoor unit compressor. It clearly lists refrigerant type and weight.

STEP 02

Review indoor model sticker

Lift the front cover of your indoor fan coil unit. A sticker on the bottom or side details the factory gas specification.

STEP 03

Check installation manual

Your original warranty booklet or user manual specifies the exact gas type required for optimal pressure.

Unsure of your unit specifications? Our certified technicians carry manifold pressure gauges to test and identify your gas on-site.
Schedule on-site check
Environmental responsibility

Better refrigerants for your home and planet

Singapore regulations favor lower-GWP refrigerants. Learn how clean refrigerant choices lower environmental impact, maintain indoor air safety, and reduce energy consumption.

Gas TypeRecommended Standard
R32 Refrigerant

Modern split units in Singapore widely adopt R32. It carries one-third the global warming potential of legacy blends and requires less volume per charge.

Global warming potential675 GWP
Ozone impact0 ODP (Zero ozone depletion)
Thermal efficiencyHigher cooling capacity
Gas TypePrevious Standard
R410A Blend

Common across existing installations. While safe for the ozone layer, its higher global warming potential is driving an industry shift toward R32.

Global warming potential2,088 GWP
Ozone impact0 ODP (Zero ozone depletion)
Thermal efficiencyStandard baseline efficiency
Gas TypePhased Out
R22 (Freon)

Banned for import in Singapore due to ozone-depleting properties. Older systems using R22 should be scheduled for replacement rather than top-ups.

Global warming potential1,810 GWP
Ozone impactDepletes ozone layer
Thermal efficiencyLow energy efficiency

Our safety and handling standards

EZ Aircon strictly adheres to local National Environment Agency (NEA) guidelines for refrigerant handling, preventing atmospheric venting during every service.

Precision leak testing

We test copper joints and valves before gas charging to avoid accidental gas release into the atmosphere.

Responsible gas recovery

Certified technicians capture existing refrigerant with dedicated recovery units during overhaul or decommissioning.

Exact factory charge

We use digital scales to charge the exact manufacturer-specified weight, maximizing cooling performance and compressor lifespan.

Eco-efficiency guidance

We inspect your system's overall health and provide honest advice on when retrofitting is more cost-effective than continuous top-ups.

Unsure which refrigerant your aircon uses?

Our technicians verify your outdoor condenser data plate during regular maintenance.

Transparent pricing

Clear gas top-up rates with a proven testing process

Restore cold airflow with authentic refrigerants and comprehensive pressure checks. We diagnose first so you only pay for what your unit truly needs.

R22 Refrigerant Top-Up
Non-Inverter Systems
Standard gas top-up suited for legacy and standard split air conditioning units.
$60per fan coil unit

Included in this package

  • Operating pressure diagnosis
  • Standard valve and joint check
  • Gas topped up to factory PSI
  • Airflow temperature test
  • 30-day workmanship assurance
Recommended for modern ACs
R410A / R32 Eco Top-Up
Most Common / Inverters
High-pressure eco refrigerant top-up formulated for modern energy-efficient inverter systems.
$80per fan coil unit

Included in this package

  • Digital dual-gauge pressure analysis
  • Electronic joint leak inspection
  • High-grade R410A / R32 gas refill
  • Current amp draw verification
  • 60-day service warranty
How we do it

Our 4-step gas top-up and testing workflow

Every appointment follows a strict technical checklist to avoid overcharging and protect your aircon compressor.

01

Operating pressure check

We attach precision manifold gauges to assess your compressor pressure and cooling delta.

02

Leak and valve inspection

Our technicians inspect flare joints and service ports to confirm there are no active refrigerant leaks.

03

Exact gas replenishment

We charge your system with pure refrigerant matched strictly to manufacturer specifications.

04

Final cooling test

We verify coil temperature, airflow output, and electrical amp draw to ensure peak cooling efficiency.

No hidden charges

Transparent rates quoted before any work starts.

Qualified technicians

Trained specialists handling high-pressure refrigerants safely.

Workmanship warranty

Every gas top-up comes with a standard service guarantee.

Not sure which refrigerant type your aircon unit uses?

Our technicians carry both R22 and R410A/R32 cylinders to every on-site service call.